PAIN BOT — Visualizing the Invisible Pain

PAIN BOT is a Class 2 medical device that objectifies and visualizes subjective pain through LED colors and pain intensity values. A single device delivers HRV autonomic nervous system testing, pain trigger point screening, TENS·ultrasound combination therapy, and pre/post-treatment value comparison. Officially certified by the Korean Balance Medicine Society. Free demo requests: 010-7173-7290

Free Demo

Officially Certified by the Korean Balance Medicine Society

Visualize the Pain

You Cannot See

Transform subjective pain into objective, measurable data — delivering pain treatment that both patients and physicians can trust, in a single device.

PAIN BOT

Pain Diagnosis & Treatment System · Class II Medical Device

Request a Demo

See the 4-Step Workflow

Why PAIN BOT

Why Pain Needs to Be Visualized

Conventional pain treatment relies on the patient's subjective description, leaving diagnosis and treatment sites ambiguous. PAIN BOT resolves this limitation through technology.

Limits of Subjective Reporting

Relying solely on the patient saying "it hurts here" makes it difficult to accurately locate the pain trigger point.

Treatment Outcomes Hard to Measure

Without numerical comparison between pre- and post-treatment, building treatment plans and communicating with patients is constrained.

Lack of Data-Driven Care

Clinics need a tool to systematically track each patient's pain history and guide treatment direction with objective data.

Diagnosis & Treatment

A 4-Step Workflow in a Single Device

From trigger point screening and focused treatment to data-based outcome verification and follow-up planning — all integrated into a single PAIN BOT device.

TrP Screening

Trigger Point Screening

Quickly and accurately locate trigger points through the probe's LED color shift and the pain-depth value displayed in the software.

TENS + Ultrasound

Focused PAIN BOT Treatment

Apply TENS (transcutaneous electrical nerve stimulation) and ultrasound to the trigger point — either independently or in combination.

Korean NHI codes: TENS MM070 · Ultrasound MM020

Pain Measurement

Pain-Depth Measurement Report

Compare pre- and post-treatment pain-depth values and generate per-patient outcome reports — confirming recovery objectively.

Follow-up Plan

Build the Follow-up Plan

Use accumulated patient data to design personalized treatment plans and manage care long-term.

Key Features

The Technology That Makes Pain Visible

So that both physician and patient can see exactly where pain is and how severe — PAIN BOT visualizes pain through three channels: light, sound, and numbers.

🔴

LED Color Indication System

LEDs on the probe and main unit turn red over trigger points — a stark contrast to the green/white shown over healthy tissue. Physician and patient can verify together.

📊

Pain-Depth Measurement Software

Monitor pain-depth values per site in real time, generate before/after comparison reports, and manage patient history through the integrated database.

⚡

TENS — Transcutaneous Electrical Nerve Stimulation

Electrical stimulation grounded in Gate Control Theory inhibits pain signaling and promotes endorphin release, supporting rapid pain relief.

🔊

1 MHz Ultrasound Therapy

Continuous-wave and pulse-wave modes deliver combined effects: pain relief, increased blood flow, faster nerve conduction, reduced muscle spasm, and improved metabolism.

🖥️

Intuitive Touchscreen Interface

A user-centered touch interface lets you adjust WATT, TIME, and VOLT effortlessly, with one-tap switching between Continuous and Pulse modes.

🏥

Optimized for the Clinical Floor

Medical-grade casters allow free movement; an integrated tray holds patches, gel, and a dedicated laptop for the pain-depth measurement software — all in one unit.

Clinical Evidence

Diagnostic Accuracy Validated in a Peer-Reviewed Journal

The clinical study was published in Diagnostics (MDPI), an SCIE/Scopus-indexed journal — formally validating PAIN BOT's diagnostic effectiveness.

94.1%

Diagnostic Accuracy

(Classification)

0.981

AUC (ROC Curve)

Resistance Model

85

Valid Data Points

Clinical Participants

95.0%

Lower-Back Pain

Detection Sensitivity

Clinical Study Summary — Before & After

Conducted June–August 2023 with 85 valid data sets out of 98 participants, the study — "Pain Measurement in Lumbar Pain Patients via Bioelectrical Impedance: A Clinical Performance Evaluation" — judged pain based on the probability of the subject experiencing lumbar symptoms, achieving 94.1% accuracy.

Case example: at first visit VAS 7, pain-depth value 15.55. After 3 PAIN BOT sessions (6 minutes total), VAS dropped to 5 and pain-depth to 14.21 — improvement confirmed.

SCIE Indexed

Scopus Indexed

Diagnostics (MDPI)

ROC AUC 0.981

Consultation Based on Clinical Data

Treatment Protocol

Structured Treatment Protocols

Build personalized treatment plans based on pain-depth values and acute/chronic classification.

TYPE I — By Pain-Depth Value

Mild (12–14)1 set, 6 min · 5 sessions

Moderate (14–17)2 sets, 12 min · 6–10 sessions

Severe (17–20)3–5 sets, 18–30 min · 15 sessions

TYPE II — By Acute / Chronic

Acute Pain2 sets, 12 min · 5 sessions

Subacute Pain1 set, 6 min · 10 sessions

Chronic Pain3–5 sets, 18–30 min · 15 sessions

Indications

Recommended for These Patients

Patients presenting with acute or chronic musculoskeletal pain

Myofascial pain syndrome symptoms — localized pain, trigger-point tenderness, referred pain

Patients undergoing prolotherapy (ligament-strengthening injections) and manual therapy

Patients receiving TPI (trigger point injection) and perineural injections

Patients requiring IMS and rehabilitation / physical therapy

Anyone seeking non-surgical pain treatment

Specifications

Product Specifications

ModelPB-101

Device ClassClass II Medical Device

Rated Frequency50 / 60 Hz

Power & ConsumptionAC 100–240 V, 60 VA

Dimensions530 (W) × 385 (D) × 1,195 (H) mm

Weight24 kg

Electrical ProtectionClass I equipment, Type BF applied part

Application AreasNeck, shoulders, arms, back, lower back, hands, legs, knees, feet

Certifications & Registrations

GMP Compliance

ISO 13485

Innovative Company Certification

Malaysia MDA

Singapore MDA

Indonesia MDA

Philippines MDA

Kyrgyzstan MDA

Korean Public Procurement Registration

Clinic Advantage

Why Bring PAIN BOT to Your Clinic Now

Pain treatment patients can see for themselves — high satisfaction is the foundation of a differentiated pain clinic.

01

Maximize Patient Satisfaction

Patients see for themselves as LEDs change color and pain-depth values shift. When "this is where it hurts" appears as data, trust and satisfaction with treatment fundamentally transform.

02

Before/After Comparisons Drive Return Visits

The pain-depth measurement software objectively compares pre- and post-treatment values. Patients confirm improvement themselves, which builds motivation to continue — and follow-up visits become natural.

03

Differentiated, Data-Driven Care

Build a pain-history database for every patient and design personalized treatment plans. Evidence-based care elevates your pain clinic's expertise and competitiveness to a new level.

04

Reimbursement-Linked Revenue Model

In the Korean market, both TENS (MM070) and Ultrasound (MM020) are covered under National Health Insurance, enabling a stable revenue structure for treatment while differentiated care strengthens overall competitiveness.

A system that identifies and treats trigger points without complex testing — and quantifies results for direct comparison. A new standard for non-surgical pain treatment, raising satisfaction for physicians and patients alike.

Contact

Experience the New Standard

in Pain Treatment Firsthand

Try PAIN BOT's LED pain visualization and pain-depth measurement software in person at your clinic. Free demonstrations and adoption consultations are welcome.

RED&BLUE Co., Ltd. — Head of Sales

+82-10-7173-7290

Call to Request a Demo

Officially Certified by the Korean Balance Medicine Society · RED&BLUE Co., Ltd. · Class II Combination Stimulator

Bio-Data & Pain Management Corporation

RED&BLUE Co., Ltd. — 73 Sangmongsandan 2-ro, Yesan-gun, Chungcheongnam-do, Republic of Korea

+82-41-338-6111

© RED&BLUE. All rights reserved.

Request a Free Demo · +82-10-7173-7290